As we've built out our automations options for the Controller, we've chosen to create guided workflows to simplify the setup process, helping Pros to get it right the first time.
Here are our available Guided Workflows:
Workflow: Residential Demand Control Ventilation - 1-Controller
Passively allows for:
- Increased Filtration (as ventilating dehumidifier's fan is set to run 24/7 to support the HAVEN Monitor's airflow needs)
IAQ & HVAC equipment needed:
- Ventilating dehumidifier
- Motorized damper
HAVEN devices needed:
- 1 Monitor
- 1 Controller
Actively manages equipment when:
tVOC levels get worse |
Humidity levels increase too much |
---|---|
Increase Ventilation when outdoor AQI (pollution) is within acceptable range |
Decrease Humidity levels based on high indoor dew point |
Increase Circulation when it's not safe to open the damper |
Requirements:
- Ventilating dehumidifier's fan is set to run 24/7 to support the HAVEN Monitor's airflow needs, while simultaneously increasing filtration
--------------------------
Workflow: Residential Demand Control Ventilation - 2-Controllers
IAQ & HVAC equipment needed:
- Central air handler
- Ventilating dehumidifier
- Motorized damper
HAVEN devices needed:
- 1 Monitor
- 2 Controllers
Actively manages equipment when:
tVOC levels get worse |
Humidity levels increase too much |
PM2.5 levels get worse |
Circulation is needed |
---|---|---|---|
Increase Ventilation when outdoor AQI (pollution) is within acceptable range |
Decrease Humidity levels based on high indoor dew point |
Increase Filtration based on high PM2.5 levels |
Increase Circulation based on Circulation Schedule |
Increase Circulation when it's not safe to open the damper |
--------------------------
COMING SOON
Workflow: Residential Demand Control Ventilation + Energy-Saving Comfort Mode
IAQ & HVAC equipment needed:
- Central air handler
- Motorized damper
HAVEN devices needed:
- 1 Monitor
- 1 Controller
Actively manages equipment when:
tVOC levels get worse |
Humidity and temperature levels get less comfortable |
PM2.5 levels get worse |
Circulation is needed |
---|---|---|---|
Increase Ventilation when outdoor AQI (pollution), outdoor temperature and outdoor humidity are within acceptable ranges |
Improve temperature and humidity levels when Outdoor Comfort Score is better than Indoor Comfort Score |
Increase Filtration based on high PM2.5 levels |
Increase Circulation based on Circulation Schedule |
Increase Circulation when it's not safe to open the damper |